Skip to content
    Hong KongBest Price6-12 Month WarrantyParcel $19+ · Free $5K+Service & SupportHong KongBest Price6-12 Month WarrantyParcel $19+ · Free $5K+Service & Support
    MinerHaolanHong Kong
    Technical Support & Hardware Diagnostics

    ASIC Miner Error Codes & Troubleshooting Hub

    Diagnose kernel-log and dashboard error messages for Bitmain, MicroBT, and Canaan hardware. Find immediate fixes, source replacement parts, or request service through our Hong Kong repair facility.

    Bitmain
    Critical
    Fan

    Fatal Error: Fan lost

    Meaning: The control board detected that one or more cooling fans stopped reporting RPM signals or is disconnected.

    Recommended Solution:Check fan 4-pin header seating on the control board. If fans spin but error persists, replace the cooling fan or test tachometer wire.
    Bitmain
    Critical
    Temperature

    temp too high / temp protect

    Meaning: Hashboard PCB or chip temperature exceeded safe operational limits (typically >85°C on PCB or >105°C on chip).

    Recommended Solution:Verify ambient room ventilation, check for dust blockage in heatsink fins, ensure intake fan speed is >5000 RPM, and check thermal paste condition.
    Bitmain
    Warning
    Network/Pool

    Socket connect failed / pool down

    Meaning: Miner cannot establish TCP connection with the configured Stratum mining pool URL and port.

    Recommended Solution:Verify local Ethernet cable, router DNS resolution, firewall port 3333/4433 status, and backup pool configuration.
    Bitmain
    Critical
    Hashboard

    Chain [J] only find [0] asic

    Meaning: Control board is unable to communicate with ASIC chips on hashboard slot J.

    Recommended Solution:Check ribbon cable connecting control board to hashboard J. If reseating fails, test hashboard voltage and PIC chip; board may require repair.
    Bitmain
    Critical
    Power/Voltage

    power init failed / PSU protect

    Meaning: APW power supply communication failed or voltage output is out of tolerance.

    Recommended Solution:Inspect C19/C20 power cables, check input voltage (must be 200–240V for industrial PSUs), and verify 12V busbar screw tightness.
    MicroBT
    Critical
    Power/Voltage

    Error 201: Power voltage abnormal

    Meaning: Whatsminer PSU detected input voltage out of safe bounds (under-voltage <180V or over-voltage >280V).

    Recommended Solution:Test PDU socket line voltage with a multimeter. Ensure 3-phase or 240V circuit is stable without excessive voltage drop under load.
    MicroBT
    Warning
    Fan

    Error 203: Fan speed abnormal

    Meaning: Whatsminer intake or exhaust fan RPM is below manufacturer threshold for current hash target.

    Recommended Solution:Inspect fan blades for dust or physical interference. Clean with compressed air; replace 14038 fan unit if RPM does not recover.
    MicroBT
    Critical
    Hashboard

    Error 206: Hashboard communication error

    Meaning: Control board lost SPI communication with one of the Whatsminer hashboard modules.

    Recommended Solution:Power cycle unit, check control board ribbon interface, clean contacts with contact cleaner, and run Whatsminer diagnostic tool.
    Canaan
    Warning
    Firmware

    MM Error: CRC check error

    Meaning: Data packet transmission between Avalon Raspberry Pi / controller and hashboard failed checksum verification.

    Recommended Solution:Reboot controller, update to latest official Canaan FMS firmware, and inspect micro-USB interconnect cabling.
    Canaan
    Warning
    Temperature

    Avalon Temp Alert: Hot Warning

    Meaning: Avalon Mini 3 or Avalon Q intake temperature is high, prompting auto-throttling to maintain silence.

    Recommended Solution:Ensure space heater airflow is not obstructed by furniture or curtains. Clean intake mesh filter.

    Need Replacement Parts or Diagnostic Assistance?

    Our Hong Kong repair facility stocks replacement control boards, power supplies, and high-RPM cooling fans.